Showing posts with label Gas Detection. Show all posts
Showing posts with label Gas Detection. Show all posts

Wednesday, March 21, 2018

Draeger Gas Detection Transmitter and Feature Selection Charts

Here are two charts to help you select Draeger Gas Detection Transmitters.

The diagram below provides a flow chart on how to properly select a Draeger transmitter.

Draeger Transmitter Selection Flow Chart
Draeger Transmitter Selection Flow Chart (click for larger view).

The table below provides a feature comparison table for most Draeger transmitters (it does not show the PointGard 2100, but the P8100 features are very similar, if not identical).

Draeger transmitter feature comparison table
Draeger transmitter feature comparison table
(click for larger view).

Wednesday, December 13, 2017

Draeger Tubes & Chip Measurement System Handbook

Draeger is the leader in industrial gas and vapor analysis and have developed more detection devices and tubes for more applications than any other gas detection company.

Draeger sampling tubes allow identification and measurement of different substances even under difficult conditions.

Draeger Chip Measurement System (CMS) combines Chips for measure specific substances with an electronic analyzer for easy-to-use spot-measurement. The analyzer combines an optical system for analyzing the color reaction with a mass flow controller and pump system.

Download the Draeger -Tubes & Chip Measurement System Handbook here.

Thursday, October 19, 2017

Centralized Gas Monitoring for Industry

Drager REGARD 7000
The Drager REGARD 7000 is a modular and highly expandable analysis system for monitoring various gases and vapors. Suitable for gas warning systems with various levels of complexity and numbers of transmitters, the Drager REGARD 7000 also features exceptional reliability and efficiency. An additional benefit is the backward compatibility with the REGARD.

For more information in Maryland or Virginia, contact Flow-Tech at 410666-3200 or visit http://www.flowtechonline.com.

Check out the video below to learn more about the Drager REGARD 7000. Thanks for watching.

Wednesday, May 24, 2017

Drager X-Zone 5500 Hazardous Gas Area Monitoring

Drager X-zone 5500
Drager X-zone 5500
The Dräger X-zone 5500 transforms the Dräger X-am 5000/5100/5600 personal gas detection instruments into innovative area gas monitoring devices for a wide range of applications. In addition to personal air monitors carried on the body, these area gas monitors are positioned where gas hazards are expected to increase the level of safety.

Wireless fenceline

Up to 25 Dräger X-Zone 5500 can be automatically interconnected to form a wireless fenceline. The interconnection of the area monitoring devices allows for rapid establishment of safety networks for larger areas. A Dräger X-zone 5500 detecting a gas alarm transmits the alarm signal to all interconnected units. A red flashing master alarm in the mother unit detecting gas contrasts with red/green flashing alarms of the connected daughter units providing simple recognition of alarm status and the actual location of the hazard.

With the corresponding configuration, the maximum gas concentration in the monitored area is shown on the display. Combined with the display of the X-zone ID a clear containment of the hazard area is possible.

Clear warning

The illuminated green LED ring indicates that the air is free of toxic and combustible gases. Upon detection of gas hazards, the LED color changes from green to red, thus providing a clear visual warning that gas is present. Additionally, a loud and highly audible evacuation alarm is emitted. The Dräger X-zone 5500 gas entry is arranged that the gas can diffuse into Dräger X-am gas monitors from all sides.

Perfect for confined spaces

An integrated pump version allows for continuous monitoring of confined spaces and locations which are difficult to access, even from a distance of up to 150 ft.

Other benefits
  • Visual 360° LED (illuminated ring) 
  • Audible 360°; > 108 dB in a distance of 1 m (30 ft.), 120 dB in a distance of 30 cm (1 ft.) 
  • Approval for Ex-Zone 0 
  • Daily function test and calibration not required after single on-site testing 
  • Individually configurable with the Dräger CC-Vision PC software (eg. alarm frequency) 
  • Inductive charging station: easy and convenient non-contact charging 
  • Continuous operation for up to 120 hours: The 24 Ah battery of the Dräger X-zone 5500 provides up to 120 hours of continuous operation – a complete working week.